Reactive Power
A sinusoidally alternating voltage applied to a purely resistive load results in an alternating current that is fully in phase with the voltage. However, in many applications it is common for there to be a reactive component to the system, that is, the system possesses capacitance, inductance, or both. These electrical properties cause the current to change phase with respect to the voltage: capacitance tending the current to lead the voltage in phase, and inductance to lag it.
For sinusoid currents and voltages at the same frequency, reactive power in vars is the product of the RMS voltage and current, or the apparent power, multiplied by the sine of the phase angle between the voltage and the current. The reactive power, (measured in units of volt-amperes reactive or var), is given by:
where is the phase angle between the voltage and current.
Only effective power, the actual power delivered to or consumed by the load, is expressed in watts. Imaginary power is properly expressed in volt-amperes reactive.
Read more about this topic: Volt-ampere Reactive
Famous quotes containing the word power:
“All goes to show that the soul in man is not an organ, but animates and exercises all the organs; is not a function, like the power of memory, of calculation, of comparison, but uses these as hands and feet; is not a faculty, but a light, is not the intellect or the will, but the master of the intellect and the will; is the background of our being, in which they lie,an immensity not possessed and that cannot be possessed.”