Ventricular Assist Device - History

History

The early VADs emulated the heart by using a "pulsatile" action where blood is alternately sucked into the pump from the left ventricle then forced out into the aorta. Devices of this kind include the HeartMate IP LVAS, which was approved for use in the US by the FDA in October 1994. These devices are commonly referred to as first generation VADs.

More recent work has concentrated on continuous flow pumps, which can be roughly categorized as either centrifugal pumps or axial flow impeller driven pumps. These pumps have the advantage of greater simplicity resulting in smaller size and greater reliability. These devices are referred to as second generation VADs. A side effect is that the user will not have a pulse, or that the pulse intensity will be seriously reduced, and will need to carry documentation saying that the lack of a pulse does not mean that they are dead.

Third generation VADs suspend the impeller in the pump using either hydrodynamic or electromagnetic suspension, thus removing the need for bearings and reducing the number of moving parts to one.

Another technology undergoing clinical trials is the use of trans cutaneous induction to power and control the device rather than using percutaneous cables. Apart from the obvious cosmetic advantage this reduces the risk of infection and the consequent need to take preventative action. A pulsatile pump using this technology has CE Mark approval and is in clinical trials for US FDA approval.

A very different approach in the early stages of development is the use of an inflatable cuff around the aorta. Inflating the cuff contracts the aorta and deflating the cuff allows the aorta to expand – in effect the aorta becomes a second left ventricle. A proposed refinement is to use the patient's skeletal muscle, driven by a pacemaker, to power this device which would make it truly self contained. However a similar operation (cardiomyoplasty) was tried in the 1990s with disappointing results. In any case, it has substantial potential advantages in avoiding the need to operate on the heart itself and in avoiding any contact between blood and the device. Interestingly this approach involves a return to a pulsatile flow.

Read more about this topic:  Ventricular Assist Device

Famous quotes containing the word history:

    What has history to do with me? Mine is the first and only world! I want to report how I find the world. What others have told me about the world is a very small and incidental part of my experience. I have to judge the world, to measure things.
    Ludwig Wittgenstein (1889–1951)

    I am ashamed to see what a shallow village tale our so-called History is. How many times must we say Rome, and Paris, and Constantinople! What does Rome know of rat and lizard? What are Olympiads and Consulates to these neighboring systems of being? Nay, what food or experience or succor have they for the Esquimaux seal-hunter, or the Kanaka in his canoe, for the fisherman, the stevedore, the porter?
    Ralph Waldo Emerson (1803–1882)

    We are told that men protect us; that they are generous, even chivalric in their protection. Gentlemen, if your protectors were women, and they took all your property and your children, and paid you half as much for your work, though as well or better done than your own, would you think much of the chivalry which permitted you to sit in street-cars and picked up your pocket- handkerchief?
    Mary B. Clay, U.S. suffragist. As quoted in History of Woman Suffrage, vol. 4, ch. 3, by Susan B. Anthony and Ida Husted Harper (1902)