Vacuum Pump - Performance Measures

Performance Measures

  • Pumping speed refers to the volume flow rate of a pump at its inlet, often measured in volume per unit of time. Momentum transfer and entrapment pumps are more effective on some gases than others, so the pumping rate can be different for each of the gases being pumped, and the average volume flow rate of the pump will vary depending on the chemical composition of the gases remaining in the chamber.
  • Throughput refers to the pumping speed multiplied by the gas pressure at the inlet, and is measured in units of pressure·volume/unit time. At a constant temperature, throughput is proportional to the number of molecules being pumped per unit time, and therefore to the mass flow rate of the pump. When discussing a leak in the system or backstreaming through the pump, throughput refers to the volume leak rate multiplied by the pressure at the vacuum side of the leak, so the leak throughput can be compared to the pump throughput.

Positive displacement and momentum transfer pumps have a constant volume flow rate (pumping speed), but as the chamber's pressure drops, this volume contains less and less mass. So although the pumping speed remains constant, the throughput and mass flow rate drop exponentially. Meanwhile, the leakage, evaporation, sublimation and backstreaming rates continue to produce a constant throughput into the system.

Read more about this topic:  Vacuum Pump

Famous quotes containing the words performance and/or measures:

    They say all lovers swear more performance than they are able, and yet reserve an ability that they never perform; vowing more than the perfection of ten, and discharging less than the tenth part of one.
    William Shakespeare (1564–1616)

    There are other measures of self-respect for a man, than the number of clean shirts he puts on every day.
    Ralph Waldo Emerson (1803–1882)