Relative Permittivity - Measurement

Measurement

The relative static permittivity, εr, can be measured for static electric fields as follows: first the capacitance of a test capacitor, C0, is measured with vacuum between its plates. Then, using the same capacitor and distance between its plates the capacitance Cx with a dielectric between the plates is measured. The relative dielectric constant can be then calculated as

For time-variant electromagnetic fields, this quantity becomes frequency-dependent and in general is called relative permittivity. An indirect technique to calculate εr is conversion of radio frequency S-parameter measurement results. A description of frequently used S-parameter conversions for determination of the frequency-dependent εr of dielectrics can be found in. Alternatively, resonance based effects may be employed at fixed frequencies.

Read more about this topic:  Relative Permittivity