The specific speed of a turbine dictates the turbine's shape in a way that is not related to its size. This allows a new turbine design to be scaled from an existing design of known performance. The specific speed is also the main criterion for matching a specific hydro-electric site with the correct turbine type.
(dimensioned parameter), = rpm
where:
- = Power (kW)
- = Water head (m)
The formula implies that the Pelton turbine is most suitable for applications with relatively high hydraulic head H, due to the 5/4 exponent being greater than unity, and given the characteristically low specific speed of the Pelton.