Overhead Line Crossing - Overhead Line Crossings of Aerial Tramways

Overhead Line Crossings of Aerial Tramways

Overhead lines should cross the route of an aerial tramway only above it, if at all.

The necessary protection distances from overhead lines to the ropes of an aerial tramway are subject to regulations concerning the construction of aerial tramways and overhead lines. In the case of an undercrossing of an aerial tramway, the maximum safety distances between the overhead line and the floor of the aerial tramway cab must be followed absolutely.

In principle, over- and undercrossings of aerial tramways are completely regulated. However, frequently at the range of the crossing section, special precautionary measures are taken. Thus, at overhead line crossings at which the overhead line runs above the rope of the aerial tramway, two catch ropes are occasionally installed to prevent the conductor from falling off the rope of the tramway in case a pylon or insulator were to break. Alternatively, auxiliary cross-bars can be installed on the pylons of the overhead line under the conductors, which prevent the conductor cables from falling in case of an insulator failure on the aerial tramway. Occasionally, the span field of the line over the aerial ropeway can be scaffolded with a rigid construction along its whole length, or at least for the span which crosses the aerial tramway.

At crossings at which the aerial tramway runs above the power line, the line is frequently installed on special masts in the crossing range, which scaffold the line in the area of the aerial tramway crossing. Such a measure is not necessary according to power line regulations, but it is often done because, in case of aerial tramway failure, it is possible to rescue people from the tram without switching off the overhead line. Such constructions may be seen at 110 kV power line crossings of the Penkenbahn at Mayrhofen, the Patscherkofelbahn at Innsbruck and south of Zermatt.

Read more about this topic:  Overhead Line Crossing

Famous quotes containing the words overhead, line and/or aerial:

    During a walk or in a book or in the middle of an embrace, suddenly I awake to a stark amazement at everything. The bare fact of existence paralyzes me... To be alive is so incredible that all I can do is to lie still and merely breathe—like an infant on its back in a cot. It is impossible to be interested in anything in particular while overhead the sun shines or underneath my feet grows a single blade of grass.
    W.N.P. Barbellion (1889–1919)

    The line that I am urging as today’s conventional wisdom is not a denial of consciousness. It is often called, with more reason, a repudiation of mind. It is indeed a repudiation of mind as a second substance, over and above body. It can be described less harshly as an identification of mind with some of the faculties, states, and activities of the body. Mental states and events are a special subclass of the states and events of the human or animal body.
    Willard Van Orman Quine (b. 1908)

    A sociosphere of contact, control, persuasion and dissuasion, of exhibitions of inhibitions in massive or homeopathic doses...: this is obscenity. All structures turned inside out and exhibited, all operations rendered visible. In America this goes all the way from the bewildering network of aerial telephone and electric wires ... to the concrete multiplication of all the bodily functions in the home, the litany of ingredients on the tiniest can of food, the exhibition of income or IQ.
    Jean Baudrillard (b. 1929)