Onsite Sewage Facility - Improving Treatment Through Performance Requirements

Improving Treatment Through Performance Requirements

Most onsite wastewater treatment systems are of the conventional type, consisting of a septic tank and a subsurface wastewater infiltration system (SWIS). Site limitations and more stringent performance requirements have led to significant improvements in the design of wastewater treatment systems and how they are managed. Over the past 20 years the Onsite wastewater treatment system (OWTS) industry has developed many new treatment technologies that can achieve high performance levels on sites with size, soil, ground water, and landscape limitations that might preclude installing conventional systems. New technologies and improvements to existing technologies are based on defining the performance requirements of the system, characterizing wastewater flow and pollutant loads, evaluating site conditions, defining performance and design boundaries, and selecting a system design that addresses these factors.

Performance requirements can be expressed as numeric criteria (e.g., pollutant concentration or mass loading limits) or narrative criteria (e.g., no odors or visible sheen) and are based on the assimilative capacity of regional ground water or surface waters, water quality objectives, and public health goals. Wastewater flow and pollutant content help define system design and size and can be estimated by comparing the size and type of facility with measured effluent outputs from similar, existing facilities. Site evaluations integrate detailed analyses of regional hydrology, geology, and water resources with sitespecific characterization of soils, slopes, structures, property lines, and other site features to further define system design requirements and determine the physical placement of system components.

Most of the alternative treatment technologies applied today treat wastes after they exit the septic tank; the tank retains settleable solids, grease, and oils and provides an environment for partial digestion of settled organic wastes. Post-tank treatment can include aerobic (with oxygen) or anaerobic (with no or low oxygen) biological treatment in suspended or fixed-film reactors, physical/chemical treatment, soil infiltration, fixed-media filtration, and/or disinfection. The application and sizing of treatment units based on these technologies are defined by performance requirements, wastewater characteristics, and site conditions.

Read more about this topic:  Onsite Sewage Facility

Famous quotes containing the words improving, treatment and/or performance:

    As in an icicle the agnostic abides alone. The vital principle is taken out of all endeavor for improving himself or bettering his fellows. All hope in the grand possibilities of life are blasted.
    Anna Julia Cooper (1859–1964)

    Narcissist: psychoanalytic term for the person who loves himself more than his analyst; considered to be the manifestation of a dire mental disease whose successful treatment depends on the patient learning to love the analyst more and himself less.
    Thomas Szasz (b. 1920)

    The way to go to the circus, however, is with someone who has seen perhaps one theatrical performance before in his life and that in the High School hall.... The scales of sophistication are struck from your eyes and you see in the circus a gathering of men and women who are able to do things as a matter of course which you couldn’t do if your life depended on it.
    Robert Benchley (1889–1945)