Ignition Magneto - Operation

Operation

In the type known as a shuttle magneto, the engine rotates a coil of wire between the poles of a magnet. In the inductor magneto, the magnet is rotated and the coil remains stationary.

On each revolution, a cam opens the contact breaker one or more times, interrupting the current, which causes the electromagnetic field in the primary coil to collapse. As the field collapses there is a voltage induced (as described by Faraday's Law) across the primary coil. As the points open, point spacing is such that the voltage across the primary coil would arc across the points. A capacitor is placed across the points which absorbs the energy stored in the primary coil. The capacitor and the coil together form a resonant circuit which allows the energy to oscillate from the capacitor to the coil and back again. Due to the inevitable losses in the system, this oscillation decays fairly rapidly.

A second coil, with many more turns than the primary, is wound on the same iron core to form an electrical transformer. The ratio of turns in the secondary winding to the number of turns in the primary winding, is called the turns ratio. Voltage across the primary coil results in a proportional voltage being induced across the secondary winding of the coil. The turns ratio between the primary and secondary coil is selected so that the voltage across the secondary reaches a very high value, enough to arc across the gap of the spark plug.

In a modern installation, the magneto only has a single low tension winding which is connected to an external ignition coil which not only has a low tension winding, but also a secondary winding of many thousands of turns to deliver the high voltage required for the spark plug(s). Such a system is known as an "energy transfer" ignition system. Initially this was done because it was easier to provide good insulation for the secondary winding of an external coil than it was in a coil buried in the construction of the magneto (early magnetos had the coil assembly externally to the rotating parts to make them easier to insulate—at the expense of efficiency). In more modern times, insulation materials have improved to the point where constructing self contained magnetos is relatively easy, but energy transfer systems are still used where the ultimate in reliability is required such as in aviation engines.

Read more about this topic:  Ignition Magneto

Famous quotes containing the word operation:

    It is critical vision alone which can mitigate the unimpeded operation of the automatic.
    Marshall McLuhan (1911–1980)

    An absolute can only be given in an intuition, while all the rest has to do with analysis. We call intuition here the sympathy by which one is transported into the interior of an object in order to coincide with what there is unique and consequently inexpressible in it. Analysis, on the contrary, is the operation which reduces the object to elements already known.
    Henri Bergson (1859–1941)

    You may read any quantity of books, and you may almost as ignorant as you were at starting, if you don’t have, at the back of your minds, the change for words in definite images which can only be acquired through the operation of your observing faculties on the phenomena of nature.
    Thomas Henry Huxley (1825–95)