Fixed Ladder - Components

Components

Fixed ladders consist of the following components:

  • Rungs: all fixed ladders have rungs, dictated by OSHA Standard 1910.27(b)(1)(ii) of no more than 12" (300 mm) on center (measured as the distance from the centerline of a rung to the center line of the next rung), and at 16" (410 mm) clear width.
  • Side members: These are the rails on the side of the ladder that are designed that the foot cannot slip off the end. Mostley flat bar or angle profile and sometimes channel.
  • Stand-off brackets: Dictated by OSHA Standard 1910.27(c)(4) stand-off brackets must be at least 7" (180 mm) longer than the farthest obstruction for clearance on the back side of ladder. This means that if there is a 4" (100 mm) gutter projecting from the side of a building, a fixed ladder would have to have standoff brackets that were at least 11" (7" + 4") (280 mm) in length.
  • Cages: Cages are optional for fixed ladders with a floor to floor elevation of less than 20' (6100 mm), however they are often available for ladders with elevation changes down to 11' (3350 mm). Cages are mandated to begin between 7' and 8'(2250 mm) from the ground and extend the entire length of the ladder. Cages can have left hand exits (opening in the LH side of cage), right hand exits(opening in RH side of cage), top exits (for exit through a hatch or floor door), and walk through exits (for exit through back side of fixed ladder). (LH or RH exits are preferred)

Read more about this topic:  Fixed Ladder

Famous quotes containing the word components:

    Hence, a generative grammar must be a system of rules that can iterate to generate an indefinitely large number of structures. This system of rules can be analyzed into the three major components of a generative grammar: the syntactic, phonological, and semantic components.
    Noam Chomsky (b. 1928)