Curtain Wall - Fire Safety

Fire Safety

Firestopping at the "perimeter slab edge", which is a gap between the floor and the backpan of the curtain wall is essential to slow the passage of fire and combustion gases between floors. Spandrel areas must have non-combustible insulation at the interior face of the curtain wall. Some building codes require the mullion to be wrapped in heat-retarding insulation near the ceiling to prevent the mullions from melting and spreading the fire to the floor above. It is important to note that the firestop at the perimeter slab edge is considered a continuation of the fire-resistance rating of the floor slab. The curtain wall itself, however, is not ordinarily required to have a rating. This causes a quandary as Compartmentalization (fire protection) is typically based upon closed compartments to avoid fire and smoke migrations beyond each engaged compartment. A curtain wall by its very nature prevents the completion of the compartment (or envelope). The use of fire sprinklers has been shown to mitigate this matter. As such, unless the building is sprinklered, fire may still travel up the curtain wall, if the glass on the exposed floor is shattered due to fire influence, causing flames to lick up the outside of the building. Falling glass can endanger pedestrians, firefighters and firehoses below. An example of this is the 1988 First Interstate Tower fire in Los Angeles, California. The fire here leapfrogged up the tower by shattering the glass and then consuming the aluminium skeleton holding the glass. Aluminium's melting temperature is 660°C, whereas building fires can reach 1,100°C. The melting point of aluminium is typically reached within minutes of the start of a fire. Firestops for such building joints can be qualified to UL 2079 -- Tests for Fire Resistance of Building Joint Systems. Sprinklering of each floor has a profoundly positive effect on the fire safety of buildings with curtain walls.

Fireman knock-out glazing panels are often required for venting and emergency access from the exterior. Knock-out panels are generally fully tempered glass to allow full fracturing of the panel into small pieces and relatively safe removal from the opening.

Read more about this topic:  Curtain Wall

Famous quotes containing the words fire and/or safety:

    I’ve seen things you people wouldn’t believe. Attack ships on fire off the shoulder of Orion. I watched seabeams glitter in the dark near the Tennhauser Gate. All those moments will be lost in time like tears in rain. Time to die.
    David Webb Peoples, U.S. screenwriter, and Ridley Scott. Roy Batty, Blade Runner, final words before dying—as an android he had a built-in life span that expired (1982)

    Firm, united, let us be,
    Rallying round our Liberty;
    As a band of brothers joined,
    Peace and safety we shall find.
    Joseph Hopkinson (1770–1842)