Efficiency Level Certifications
80 Plus test type | 115V internal non-redundant | 230V internal redundant | ||||||
---|---|---|---|---|---|---|---|---|
Fraction of rated load | 10% | 20% | 50% | 100% | 10% | 20% | 50% | 100% |
80 Plus | 80% | 80% | 80% | |||||
80 Plus Bronze | 82% | 85% | 82% | 81% | 85% | 81% | ||
80 Plus Silver | 85% | 88% | 85% | 85% | 89% | 85% | ||
80 Plus Gold | 87% | 90% | 87% | 88% | 92% | 88% | ||
80 Plus Platinum | 90% | 92% | 89% | 90% | 94% | 91% | ||
80 Plus Titanium | 90% | 94% | 96% | 91% |
Redundant are typically used in data centers.
For the higher certification levels, the requirement of 0.9 or better power factor was extended to apply to 20% and 50% load levels, as well as at 100% load. The Platinum level requires 0.95 or better power factor for servers.
The Climate Savers Computing Initiative efficiency level targets for workstations for 2007 through 2011, correspond to the 80 Plus certification levels. From July 2007 through June 2008, basic 80 Plus level (Energy Star 4.0). For next year target is, 80 Plus Bronze level, the following year 80 Plus Silver, then 80 Plus Gold, and finally Platinum.
Read more about this topic: 80 PLUS
Famous quotes containing the words efficiency and/or level:
“Nothing comes to pass in nature, which can be set down to a flaw therein; for nature is always the same and everywhere one and the same in her efficiency and power of action; that is, natures laws and ordinances whereby all things come to pass and change from one form to another, are everywhere and always; so that there should be one and the same method of understanding the nature of all things whatsoever, namely, through natures universal laws and rules.”